Working environmentThe design of pneumatic fittings should allow the free flow of required air or gas without any oppor
Pneumatic transmission and control technology, referred to as pneumatic, is the compressed air as the working medium to
In 2004, due to the persistence of the pneumatic industry, we established BLCH Pneumatic & Technology Co., Ltd. Suddenly
One of the important parts of the pneumatic components is the cylinder. In order to ensure the normal use of the cylinde
Tubing typeWhen deciding how to choose your pneumatic fittings, you need also to determine what type and size of tubing
Sports make people happy, sports make people healthy. In addition to busy work, we set up BLCH Running Team in 2022.
The overall cost to replace the shift solenoid in an automatic transmission ranges from $200 to $500 for a single solenoid. If the damage requires you to replace the entire solenoid pack the cost increases to between $250 and $700
The solenoid valve should be installed with the inlet port (usually marked as port 1) connected to the upstream flow and the outlet port (usually marked as port 2) connected to downstream. Some solenoid valves will also be marked with an arrow on the body indicating the direction the media should flow.
A proportional control valve is a valve used to control fluid flow rate by varying the size of the flow passage via a restrictor. The regulated flow rate subsequently adjusts parameters affecting a process in a system, mainly level, pressure and temperature.
A latching relay is a type of relay that can maintain its position without being continuously energized, which makes it useful in applications where power consumption needs to be minimized. It uses a magnetic mechanism to "latch" into position and hold that position until a new signal is received. This is typically accomplished by using two coils that operate in opposite directions, with one coil used to set the position of the relay and the other used to reset it. When the set coil is energized
How do you reset a solenoid valve? On regular solenoid valves, it can be switched back to the operating position by energizing the solenoid, while on solenoid valves with latch-lock function it will not be so. After being energized, the valve must be manually reset by pushing the reset-knob
It works on the principle of electromagnetism. The electromagnetic field that creates the temporary magnetic field is energised when the relay's circuit detects the fault current. This magnetic field moves the relay armature to open or close connections.