Select the correct cylinder according to the following conditions:1. According to the type of cylinder:Choose the type o
Compressed Air SupplyAdequate sizing of compressors and feed lines is the first place to start to ensure proper system o
REED SENSORSReed sensors have been in use for many years and are the most common type used in pneumatic cylinders. They'
In 2004, due to the persistence of the pneumatic industry, we established BLCH Pneumatic & Technology Co., Ltd. Suddenly
DIFFERENT TYPES OF FITTINGSFittings come in all shapes and sizes, and can be connected in a variety of ways. Shaped fitt
As the flagship exhibition of the "Hannover Industrial Expo" in Türkiye, since the "the Belt and Road" strategy was pr
The solenoid valve should be installed with the inlet port (usually marked as port 1) connected to the upstream flow and the outlet port (usually marked as port 2) connected to downstream. Some solenoid valves will also be marked with an arrow on the body indicating the direction the media should flow.
A latching relay is a type of relay that can maintain its position without being continuously energized, which makes it useful in applications where power consumption needs to be minimized. It uses a magnetic mechanism to "latch" into position and hold that position until a new signal is received. This is typically accomplished by using two coils that operate in opposite directions, with one coil used to set the position of the relay and the other used to reset it. When the set coil is energized
A proportional control valve is a valve used to control fluid flow rate by varying the size of the flow passage via a restrictor. The regulated flow rate subsequently adjusts parameters affecting a process in a system, mainly level, pressure and temperature.
Rusting, power failure, irregular pressure, missing equipment, an incorrect amount of voltage or current, dirt stuck in the system and corrosion are some of the possible reasons why a solenoid valve may not properly close or open.
One of the important parts of the pneumatic components is the cylinder. In order to ensure the normal use of the cylinder and avoid unnecessary situations, for the use of the pneumatic components and cylinder, let’s check the right way to use cylinder. When using the cylinder, the air quality requirements are very high. Clean, dry compressed air should be used. The air should not contain organic solvents, synthetic oils, salts, corrosive gases, etc., in order to avoid bottle and valve failure.
A solenoid is a device comprised of a coil of wire, the housing and a moveable plunger (armature). When an electrical current is introduced, a magnetic field forms around the coil which draws the plunger in. More simply, a solenoid converts electrical energy into mechanical work.