We blch team look forward to meeting you in São Paulo, Istanbul,Bangkok,Yekaterinburg in 2023,we also looking for agenci
From May 5th to 6th, 2023, more than 30 sales staff of BLCH Pneumatic gathered at the headquarters to attend the May sal
Compressed Air SupplyAdequate sizing of compressors and feed lines is the first place to start to ensure proper system o
Dear all friends and customer,Happy Chinese New YearWe BLCH pneumatic Teamwish you lucky in the year of OXsafety & peace
Tubing typeWhen deciding how to choose your pneumatic fittings, you need also to determine what type and size of tubing
Tubing typeWhen deciding how to choose your pneumatic fittings, you need also to determine what type and size of tubing
One of the important parts of the pneumatic components is the cylinder. In order to ensure the normal use of the cylinder and avoid unnecessary situations, for the use of the pneumatic components and cylinder, let’s check the right way to use cylinder. When using the cylinder, the air quality requirements are very high. Clean, dry compressed air should be used. The air should not contain organic solvents, synthetic oils, salts, corrosive gases, etc., in order to avoid bottle and valve failure.
Rusting, power failure, irregular pressure, missing equipment, an incorrect amount of voltage or current, dirt stuck in the system and corrosion are some of the possible reasons why a solenoid valve may not properly close or open.
The overall cost to replace the shift solenoid in an automatic transmission ranges from $200 to $500 for a single solenoid. If the damage requires you to replace the entire solenoid pack the cost increases to between $250 and $700
A latching relay is a type of relay that can maintain its position without being continuously energized, which makes it useful in applications where power consumption needs to be minimized. It uses a magnetic mechanism to "latch" into position and hold that position until a new signal is received. This is typically accomplished by using two coils that operate in opposite directions, with one coil used to set the position of the relay and the other used to reset it. When the set coil is energized
A proportional control valve is a valve used to control fluid flow rate by varying the size of the flow passage via a restrictor. The regulated flow rate subsequently adjusts parameters affecting a process in a system, mainly level, pressure and temperature.
A solenoid is a device comprised of a coil of wire, the housing and a moveable plunger (armature). When an electrical current is introduced, a magnetic field forms around the coil which draws the plunger in. More simply, a solenoid converts electrical energy into mechanical work.